2025.05.13
In our regular production, Fugo most commonly follows the ASTM or GB standard, but if customers have specific technical requirements, Fugo can also manufacture according to those needs. Below is a comparison of commonly used titanium-steel clad plate standards.
Specification | ASTM Standard (B898) Standard Specification for Reactive and Refractory Metal Clad Plate | EN Standard (EN 13445-2) Annex D Technical delivery conditions for clad products or pressure purposes | GB Standard (GB/T8546) Titanium Clad Stainles Steel Plate | GB Standard (GB/T 8547) Titanium Clad Steel Plate |
Tensile Strength (Min)
| In accordance with base mterial specification. | Tensile tests in accordance with EN ISO 6892-1
| In accordance with the formula in GB/T 8546
| When Titanium Cladding layer is not a part of Design Strength Requirement. Which means total Clad Plate>38.1mm, in accordance with the spec of base layer. When Cladding Cladding layer is Part of Design Strength Requirement. Which means total Clad Plate≤38.1mm,in accordance with the formula in GB/T 8547
|
Elongation (A)%
| NA | In the case of clad steels where the cladding has a lower degree of elasticity than that of the base metal, a tensile test on the cladding after the base has been removed should show an elongation after fracture A5 of at least 12 %. | In accordance with the spec of Titanium layer or base layer,whichever is the lower. | In accordance with the spec of Titanium layer or base layer, whichever is the lower. |
Shear Strength | ≥137.9 MPa (Performed when specified by the purchaser) | The shear strength of cladding with a tensile strength of less than 280 MPa should be more than half the minimum tensile strength of the cladding material and, for all other cladding materials, should not be less than 140 MPa, regardless of the direction of testing. |
|
|
Bending Test | Ductility bend tests Side bend tests (Performed when specified by the purchaser) | Bend tests on test pieces which, as shown in Figure D.5-2 cover the bonded zone and are bent in a direction parallel to the bounding zone |
(Performed in accordanc with the class level or speficified by the purchaser) |
(Performed in accordance with the class level or speficified by the purchaser) |
* This comparison now reflects the correct standards for titanium-steel clad plates. For the complete version, please refer to the latest version of the relevant standard.